Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
1.
Arq. bras. oftalmol ; 72(3): 346-350, May-June 2009. ilus, graf, tab
Artigo em Inglês | LILACS | ID: lil-521469

RESUMO

PURPOSE: To determine calibration errors of Goldmann applanation tonometers in ophthalmic clinics of Brasília, Brazil, and correlate the findings with variables related to tonometers model and utilization. METHODS: Tonometers from ophthalmic clinics in Brasília, Brazil, were checked for calibration errors. A standard Goldmann applanation tonometer checking tool was used to asses the calibration error. Only one trained individual made all verifications, with a masked reading of the results. Data on the model, age, daily use, frequency of calibration checking and the nature of the ophthalmic department - private or public - were collected and correlated with the observed errors. RESULTS: One hundred tonometers were checked for calibration. Forty seven percent (47/100) were out of 1 mmHg range at least at one point checking. Tonometers mounted to slit lamp, with less than 5 years, used in less than 20 patients daily, that had a calibration check on a yearly basis, and those from private office exhibit a lower rate of inaccuracy, but only the first variable was statistically significant. Sixty one percent of tonometers on public hospitals were out of calibration. CONCLUSION: Calibration of tonometers in the capital of Brazil is poor; those from general hospitals are worst, and this fact can lead to inaccurate detection and assessment of glaucoma patients, overall in the population under government assistance.


OBJETIVOS: Determinar os erros de calibração dos tonômetros de aplanação de Goldmann em clínicas oftalmológicas de Brasília, Brasil, e correlacioná-los a variáveis relativas ao modelo e à utilização dos aparelhos. MÉTODOS: Tonômetros de clínicas oftalmológicas de Brasília tiveram a calibragem aferida usando um cilindro padrão fornecido pelo fabricante dos aparelhos. Todas as aferições foram realizadas por um só examinador previamente treinado e a leitura das medidas foi mascarada por um observador independente. As medidas foram correlacionadas ao modelo, idade, utilização diária e frequência de aferição da calibração dos tonômetros, bem como o serviço em que o aparelho era utilizado - público ou privado. RESULTADOS: Cem tonômetros foram avaliados. Quarenta e sete por cento (47/100) apresentaram erros de leitura maiores ou iguais a 1 mmHg em pelo menos um ponto de aferição, sendo considerados descalibrados. Tonômetros fixos à lâmpada de fenda, com menos de 5 anos de fabricação, usados em menos de 20 pacientes por dia, que tinham a calibragem aferida ao menos anualmente e que eram utilizados em clínicas privadas apresentaram menos descalibragem, porém apenas a primeira variável foi estatisticamente significante. Sessenta e um por cento dos tonômetros de hospitais públicos estavam descalibrados. CONCLUSÕES: A calibragem de tonômetros avaliados em Brasília é precária. A situação é pior nos aparelhos dos hospitais públicos, podendo levar a erros na detecção e no acompanhamento de pacientes com glaucoma atendidos nesses serviços.


Assuntos
Humanos , Tonometria Ocular/instrumentação , Brasil , Estudos Transversais , Calibragem/normas , Análise de Falha de Equipamento/métodos , Hospitais Privados/estatística & dados numéricos , Hospitais Públicos/estatística & dados numéricos , Oftalmologia , Controle de Qualidade , Tonometria Ocular/normas
2.
Arq. bras. oftalmol ; 70(5): 797-802, set.-out. 2007. tab, mapas, graf
Artigo em Português | LILACS | ID: lil-470097

RESUMO

OBJETIVO: Avaliar as consultas realizadas em um serviço de emergência oftalmológica em Brasília, Distrito Federal, Brasil, durante o período de um mês. MÉTODOS: Revisão retrospectiva de prontuários de pacientes atendidos no período entre 1 e 30 de setembro de 2003 no Pronto Socorro Oftalmológico do Hospital de Base de Brasília. RESULTADOS: A idade média dos pacientes foi de 32,9 ± 18,0 anos (variando entre zero e 90). Setenta por cento dos pacientes pertenciam ao grupo de população economicamente ativa (20 aos 59 anos). Sessenta e dois por cento dos pacientes atendidos pertenciam ao sexo masculino (n=1.777) e 38 por cento ao sexo feminino (n=1.067). Dezessete por cento do pacientes atendidos procederam de outros estados, 83 por cento possuíam endereço domiciliar no próprio Distrito Federal. Em 3 por cento dos prontuários não constavam endereços. Dos pacientes residentes no próprio DF, 84 por cento procederam de localidades distantes pelo menos 30 km do local da emergência. Traumas oculares de qualquer natureza foram as doenças mais freqüentes (n=730/30 por cento), seguidos por conjuntivites (n=568/24 por cento). Em 457 (16 por cento) prontuários não houve qualquer preenchimento. CONCLUSÃO: O serviço público de emergência oftalmológica do DF está mal localizado. A grande maioria dos pacientes se apresenta com doenças de menor importância. Estes fatos somados ao excesso de fichas em branco demonstram que o sistema público de saúde em oftalmologia do Distrito Federal necessita de mudanças.


PURPOSE: To evaluate all the visits to the ophthalmic emergency service in Brasília, Distrito Federal, Brazil, through a 1-month period. METHODS: A retrospective chart review was carried out of all patients attending the ophthalmology emergency department of the "Hospital de Base de Brasília" during September 1 to 30, 2003. RESULTS: Mean age was 32.9 ± 18.0 years (ranging from zero to 90). Seventy per cent of patients were of the working age category (from 20 to 59 years-old). Sixty-two per cent of the patients were male (n=1,777) and 38 percent female (n=1,067). Seventeen per cent of the patients lived in another state, and 83 percent lived in the Distrito Federal itself. In 3 percent of the charts, no address was informed. In the group of patients residents of the Distrito Federal, 84 percent lived at least 30 km away from the "Hospital de Base". Ocular traumas of any nature were the most frequent occurrence (n=730/30 percent), followed by conjunctivitis (n=568/24 percent). Doctors have not filled out 457 charts (16 percent). CONCLUSION: The ophthalmic emergency service of the "Hospital de Base" de Brasília is not properly located. The great majority of patients presented with common pathologies, emphasizing the need for a primary care system. This aspects plus the lack of information in a great number of charts suggests that the ophthalmic public health system in the "Distrito Federal" requires changes.


Assuntos
Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Criança , Pré-Escolar , Feminino , Humanos , Lactente , Recém-Nascido , Masculino , Pessoa de Meia-Idade , Serviço Hospitalar de Emergência , Oftalmopatias/diagnóstico , Visita a Consultório Médico/estatística & dados numéricos , Oftalmologia/estatística & dados numéricos , Brasil/epidemiologia , Conjuntivite/diagnóstico , Conjuntivite/epidemiologia , Demografia , Serviço Hospitalar de Emergência/normas , Oftalmopatias/epidemiologia , Traumatismos Oculares/diagnóstico , Traumatismos Oculares/epidemiologia , Prevalência , Estudos Retrospectivos , Fatores de Tempo , Revisão da Utilização de Recursos de Saúde
3.
Arq. bras. oftalmol ; 66(4): 431-435, jul.-ago. 2003. tab
Artigo em Inglês | LILACS | ID: lil-348163

RESUMO

PURPOSE: To study intraocular pressure (IOP) variations in healthy volunteers after weight lifting, in the supine position. METHODS: A descriptive study was designed. Thirty-four individuals were preselected for this study, and a group of 25 volunteers fulfilled the inclusion criteria for joining the initial phase of this research. All of them were healthy without glaucoma. They were asked to lift an 85 percent top load in the supine position for 8 times. IOP was measured before and after the exercise. Student's t test was used to analyze the IOP variations. RESULTS: A small, but significant IOP decrease (1.61 mmHg) was obtained after exposing 25 individuals (49 eyes) to a specific physical effort. CONCLUSIONS: After a session of weight lifting in the supine position with 85 percent top load for 8 repetitions, there is a small, but significant IOP decrease


Assuntos
Humanos , Adulto , Pressão Intraocular , Esportes , Levantamento de Peso , Epidemiologia Descritiva
4.
Rev. bras. oftalmol ; 54(7): 498-503, jul. 1995. ilus, tab
Artigo em Português | LILACS | ID: lil-279985

RESUMO

Projeto piloto de atendimento oftalmológico clínico/cirúrgico realizado no próprio local onde vive a populaçäo. Foram estudados 243 pacientes, 36 cirurgias realizadas, no período de 23 a 27 de julho de 1994, no município de Säo Félix do Araguaia (MT). Este estudo foi desenvolvido obedecendo a rotina de exame ocular completo, tendo sido realizado tratamento clínico/cirúrgico nos pacientes que deles mais necessitavam


Assuntos
Humanos , Diagnóstico Clínico , Oftalmologia/organização & administração , Projetos Piloto
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA